SUGGESTED RPOCEDURE
- Temporarily assemble adapter (1) to connector.
- Place remaining adapter components on cable in
sequence shown (except elbow). Keep these components
away from termination, so they will not ineterfere
with subsequent assembly steps.
- Insert cable into adapter (1), bottoming on connector
insert. (assemble elbow onto adapters temporarily
for this step). Slide first ring down and hold against
back of adapter (1) or (2) and mark cable at rear of ring.
- Loosen adapter (1) from connector, slide ring
and adapter up cable with theother components.
(remove elbow, sliding adapters (1) & (2) and ring up cable).
- Trim cable jacket (if applicable) approx. 1 to 1-1/2 inches
in back of mark made (step 3). Be sure trim
length allows clamp gland to make full contact
with cable jacket, to insure proper environmental
seal.
- Prepare shielding by either combing or flaring out.
extract individual shield pig tails (if applicable) and
flatten out. Fold back and spot tie or tape
prepared shields temporarily on cable.
- Prepare and terminate conductors in accordance
with normal practices.
- Tighten adapter (1) securely to connector
(assemble elbow onto adapters and secure). Slide
first RFI into place. Untie shielding and arrance
evenly about cone at rear of first ring. Spot tie
shielding and trim excess.
- Slide second RFI ring and sleeve into place and
tighten securely. Slide gland and ring into place.
Slide cable and tighten being careful not to
damage cable.
- Inspect final assembly for proper installation.
NOTES: 1. Elastomers should always be lubricated prior
to assembly, to avoid damage and insure proper
sealing.
2. 90° sub-assembly (shown). Assembly procedure is
the same for 45° elbow.

|