    SUGGESTED RPOCEDURE
  1. Temporarily assemble adapter (1) to connector.
  2. Place remaining adapter components on cable in sequence shown (except elbow). Keep these components away from termination, so they will not ineterfere with subsequent assembly steps.
  3. Insert cable into adapter (1), bottoming on connector insert. (assemble elbow onto adapters temporarily for this step). Slide first ring down and hold against back of adapter (1) or (2) and mark cable at rear of ring.
  4. Loosen adapter (1) from connector, slide ring and adapter up cable with theother components. (remove elbow, sliding adapters (1) & (2) and ring up cable).
  5. Trim cable jacket (if applicable) approx. 1 to 1-1/2 inches in back of mark made (step 3). Be sure trim length allows clamp gland to make full contact with cable jacket, to insure proper environmental seal.
  6. Prepare shielding by either combing or flaring out. extract individual shield pig tails (if applicable) and flatten out. Fold back and spot tie or tape prepared shields temporarily on cable.
  7. Prepare and terminate conductors in accordance with normal practices.
  8. Tighten adapter (1) securely to connector (assemble elbow onto adapters and secure). Slide first RFI into place. Untie shielding and arrance evenly about cone at rear of first ring. Spot tie shielding and trim excess.
  9. Slide second RFI ring and sleeve into place and tighten securely. Slide gland and ring into place. Slide cable and tighten being careful not to damage cable.
  10. Inspect final assembly for proper installation. NOTES: 1. Elastomers should always be lubricated prior to assembly, to avoid damage and insure proper sealing. 2. 90° sub-assembly (shown). Assembly procedure is the same for 45° elbow.


Josyln Sunbank Company LLC 1740 Commerce Way Paso Robles, CA 93446 Tel:(805)238-2840 FAX:(805)238-0241
email us Sales / Marketing