Home
Self Seating - our patented anti-decoupling solution
Flexible Conduit Systems
Rectangular Accessories
Composite Accessories
SE-UNI Adapter
Technical Solutions Representatives
Distributor Partners
Request for Quote
Catalogs
MIL-C-85049
FAA - PMA List
Build a Backshell
Quality Policy
Air-Dry Company
Job Opportunities
Parts Available Now and Distributor Inventories
Fiber Optic Connectors and Accessories

Search By Part Number


 


CLICK HERE TO VIEW A LARGER IMAGE

EXAMPLE BASIC PART NUMBER


click here for SERIES CODE INFORMATION

ORDER NUMBERC MAX DIA D MAX DIMMAX ENTRY SIZEE MAX DIA
01 - 08, 51, 52, 64, 65.906.71928.906
09 - 11, 53, 54, 671.031.781441.031
12 - 14, 55, 56, 691.188.844501.156
15, 16, 57, 58, 701.281.906621.344
17, 18, 59, 711.4691.000871.594
19 - 28, 49, 60 - 62, 72 - 771.7811.0941001.906
29 - 31, 50, 54, 59, 60, 632.0621.2811251.906
32 - 48CONSULT FACTORY ON AVAILABILITY
    
ENTRY
SIZE
TUBE
SIZE
F ± .031
DIA
28.281.750
37.375.875
44.438.938
50.5001.000
62.6251.125
75.7501.312
87.8751.438
1001.0001.562
1251.2501.812


    NOTES:
  1. Identified Per MIL-STD-130
  2. Plating Index for Finishes Available
  3. Material; Adapter Components; Aluminum Alloy Per QQ-A-225 or QQ-A-591. Split Bushing; Nylon
  4. Insert Letter; 'L'-Part less split bushing. 'A' - Mates to annular convoluted tubing (Raychem). (see SE60
  5. Consult factory for availability of order numbers 32 thru 48
  6. Insert letter 'R' for adapter with (3) Ring Dual termination for individual and overall shields. Omit 'R' for standard (2) ring termination for individual or overall shield. Insert letter 'N' for non-RFI, RFI rings omited
  7. Insert letter 'L' in part number for adapter less drain holes.
DIMENSIONS ARE IN INCHES
Tolerance, unless otherwise specified:
.X ± .03 (1.5)
.XX ± .010 (0.8)
.XXX ± .005 (0.4)
Angles: ± 5 degrees
Fractions ± 1/32


Click here for this part's assembly procedure (AP9)


Josyln Sunbank Company LLC 1740 Commerce Way Paso Robles, CA 93446 Tel:(805)238-2840 FAX:(805)238-0241
email us Sales / Marketing