Table III
Connector Designator Shell Size |   |
A1, F2, L1,X2 | F5 | E Maximum Dimension | F Maximum Dimension | G Maximum Dimension | H Maximum Dimension |
| 8 | 9 | 0.612 (15.5) | 1.300 (33.0) | 0.727 (18.5) | 1.499 (38.1) |
| 10 | 11 | 0.675 (17.1) | 1.328 (33.7) | 0.831 (21.1) | 1.561 (39.6) |
| 12 | 13 | 0.698 (17.7) | 1.351 (34.3) | 0.886 (22.5) | 1.619 (41.1) |
| 14 | 15 | 0.723 (18.4) | 1.376 (35.0) | 0.946 (24.0) | 1.677 (42.6) |
| 16 | 17 | 0.748 (19.0) | 1.401 (35.6) | 1.008 (25.6) | 1.735 (44.1) |
| 18 | 19 | 0.767 (19.5) | 1.420 (36.1) | 1.052 (26.7) | 1.796 (45.6) |
| 20 | 21 | 0.793 (20.1) | 1.446 (36.7) | 1.115 (28.3) | 1.866 (47.4) |
| 22 | 23 | 0.818 (20.8) | 1.471 (37.4) | 1.177 (29.9) | 1.919 (48.7) |
| 24 | 25 | 0.844 (21.4) | 1.497 (38.0) | 1.240 (31.5) | 1.987 (50.5) |
*For connector family identification details click here. Consult factory for availablitiy of other connector designators not shown above.
Table IV
| Entry | J | K | L | CABLE RANGE |
| Size | MAXIMUM | MAXIMUM | MAXIMUM | MIN | MAX |
| 3 | 1.219 (31.0) | 0.812 (20.6) | 0.578 (14.7) | 0.156 (4.0) | 0.219 (5.6) |
| 4 | 1.219 (31.0) | 0.937 (23.8) | 0.578 (14.7) | 0.188 (4.8) | 0.312 (7.9) |
| 6 | 1.219 (31.0) | 1.062 (27.0) | 0.578 (14.7) | 0.250 (6.4) | 0.438 (11.1) |
| 8 | 1.219 (31.0) | 1.188 (30.2) | 0.578 (14.7) | 0.312 (7.9) | 0.531 (13.5) |
| 10 | 1.281 (32.5) | 1.132 (33.3) | 0.594 (15.1) | 0.375 (9.5) | 0.625 (15.9) |
| 12 | 1.281 (32.5) | 1.562 (39.7) | 0.656 (16.7) | 0.500 (12.7) | 0.750 (19.1) |
| 16 | 1.406 (35.7) | 1.750 (44.5) | 0.656 (16.7) | 0.700 (17.8) | 0.938 (23.8) |
| 20 | 1.656 (42.1) | 2.250 (57.2) | 0.734 (18.6) | 0.926 (23.5) | 1.250 (31.8) |
| 24 | 1.906 (48.4) | 2.375 (60.3) | 0.953 (24.2) | 1.125 (28.6) | 1.375 (34.9) |
| 28 | 1.906 (48.4) | 2.625 (66.7) | 0.953 (24.2) | 1.312 (33.3) | 1.625 (41.3) |
| 32 | 2.000 (50.8) | 2.812 (71.4) | 1.093 (27.8) | 1.500 (38.1) | 1.875 (47.6) |
Notes:
- Metric Dimensions are shown in ( ) parentheses for reference only.
- O Ring not supplied on connector designators A1 and L1. F2 is moisture proof only.
- Cable range is defined as the envelope area of the cable or wire bundle. It is not intended for inspection criteria.
Tolerance, unless otherwise specified:
|
.X ± .060 (1.5) .XX ± .030 (0.8) .XXX ± .015 (0.4) Angles: ± 5 degrees
|   |

|